Information for Reports Error Code REP-01268: Graph {0} references a bind column {1} at the wrong frequency.
Oracle® Reports Error REP-0126816/10

REP-01268: Graph {0} references a bind column {1} at the wrong frequency.


Cause: The column specified for the graph is in a group below that of the repeating frame that encloses the graph.


Action: Move the graph into a repeating frame whose source group is at or above the group that contains the specified column. Otherwise, move the specified column into the enclosing repeating frame's group, if possible.

Level: 1

Impact: Other