Oracle® Database 8i | 9i | 10g | 11g | 12c | 18c | 19c Error Codes

Information for Database Error Code ORA-16822: new primary database not yet ready for standby database reinstatement
Oracle® Database Error ORA-168221973/15

ORA-16822: new primary database not yet ready for standby database reinstatement

Cause: The new primary database, as a result of a logical standby database failover operation, had not fully completed the failover operation. An attempt to reinstate a disabled standby database could not be completed until failover completed on the new primary database.

Action: Wait until the failover operation has completed on the new primary database. Then retry the reinstate operation.

Error Type: ORA

Oracle® Database Error Codes 8i | 9i | 10g | 11g | 12c | 18c | 19c

Record: 1/1