Information for Reports Error Code REP-01517: Column {0} references column {1}, which has incompatible frequency.
Oracle® Reports Error REP-0151733/12

REP-01517: Column {0} references column {1}, which has incompatible frequency.


Cause: A column in the data model references another column (for example, in the Formula field) in the data model, but the two columns are assigned to incompatible groups. For example, if a formula column with a Group of Report referenced a column with a Group of G_Emp, this error is raised.


Action: Remove the column reference, or assign the referencing column to a group that is compatible with the group of the referenced column.

Level: 1

Impact: Other